The electric actuator failure in addition to the common short circuit or open circuit, servo amplifier and motor failure.
Common faults are analyzed as follows.hose adapters
1. Loose connectors or wiring open or short circuit. Cause poor contact, and increase or reduce the line impedance. The Troubleshooting method is checking and the toggle connecting wires, and re-plug and insert each connector.
Reducer mechanical transmission parts. Check is functioning properly, the gear meshing whether good troubleshooting is to replace or repair a broken gear lubricant.
(3) power supply. Check for blown fuses, the servo amplifiers position feedback or without smoke and special smell, such as the the transformer housing insulation and resistance charred issue burnt taste. The Troubleshooting method is the replacement of damaged components.standard air cylinder