Gas safety valve is a device for supporting new gas pipeline project. Used to cut, turned, adjusting the gas pipeline, with good control characteristics and closed sealing performance.
2013年4月27日星期六
Solenoid valve power does not work
Check the power wiring is bad → re-wiring and connectors to connect
Check whether the supply voltage is in the range of ± work - → tone caused by normal position range
The coil whether sealing off → re-welding
Coil short → Replace the coil
Working pressure is inappropriate → adjust the differential pressure → commensurate with or replace the solenoid valve
Fluid temperature is too high → Replace the solenoid valve commensurate
Impurities solenoid valve main spool and dynamic core stuck cleaning → if the seal is damaged replace the seal and install the filter
Liquid viscosity is too large, the frequency is too high, and life replacement product to →pneumatic hand valve
Solenoid valve can not be closed
The main spool or moving iron core seals damage → Replace the seals
Fluid temperature, the viscosity is too high → counterparts replacement solenoid valve
Cleaning impurities into the solenoid valve spool production or moving core →
Spring to life or deformation → Replace
The throttle Kong Pingheng clogging → timely cleaning
Working frequency is too high or too the life → reelection products or updated products
Other
Internal leakage → Check the seals for damage, the spring assembly of non
The external leakage → loose connections or seal has been broken → screws or replace the seals
Energized noise → chieftain fasteners to loosen and tighten. Voltage fluctuation is not within range, adjust the voltage. The core pull surface impurities or uneven, cleaned or replaced in a timely manner.stainless steel pneumatic cylinders